6. APPLICATION FUNCTIONS 
 
6.31.3 Control mode switch 
For control mode switch, there are the two following methods that can be selected for both "switching from 
position control mode to continuous operation to torque control mode" and "switching from continuous 
operation to torque control to position control mode" 
• Automatic switch 
• Manual switch 
 
(1) Control mode switch setting 
The setting contents and setting values required for each switch pattern are shown in the following table. 
 
Switch pattern 
Switch method 
Setting items 
Setting values 
Switching from position 
control mode to 
continuous operation to 
torque control mode 
Automatic switch  Continuous operation to torque 
control switching position 
Position to switch to continuous operation to torque 
control mode [command units] 
Start switch to continuous operation 
to torque control condition 
0000h, 0001h: Automatic switch 
(position command) 
0010h, 0011h: Automatic switch 
(current feedback position) 
Manual switch 
Start switch to continuous operation 
to torque control condition 
0002h, 0012h: Manual switch 
Switching from 
continuous operation to 
torque control  mode to 
position control mode 
Automatic switch  End switch to continuous operation 
to torque control condition 
0000h to 0002h: Automatic switch 
Manual switch 
End switch to continuous operation 
to torque control condition 
0010h to 0012h: Manual switch 
 
(2) Procedure for switching from position control mode to continuous operation to torque control mode 
(a) Switch method: Automatic switch 
1) The position board automatically switches the control mode thus processing by user program is not 
required. 
(The position board determines the continuous operation to torque control switching position, and 
automatically switches to continuous operation to torque control mode once the position is reached.) 
 
(b) Switch method: Manual switch 
1) Set the control mode command to "3: Continuous operation to torque control mode". 
2) Turn ON control mode switch command (CTLMC). (Have the switch timing determined by user 
program) 
3) After confirming control mode switch complete (CTLMCF) is ON, turn OFF control mode switch 
command (CTLMC). 
 
(3) Procedure for switching from continuous operation to torque control mode to position control mode  
(a) Switch method: Automatic switch 
1) The position board automatically switches the control mode thus processing by user program is not 
required. 
(Control mode is automatically returned to position control mode after the press time has passed 
since the starting of torque output within the torque settle width of the target torque.) 
 
(b) Switch method: Manual switch 
1) Set the control mode command to "0: Position control mode". 
2) Turn ON control mode switch command (CTLMC). (Have the switch timing determined by user 
program) 
3) After confirming control mode switch complete (CTLMCF) is ON, turn OFF control mode switch 
command (CTLMC).