1. SUMMARY 
 
(8) Setting, monitoring, and testing through test tool 
Using the test tool of Position Board Utility2 (MRZJW3-MC2-UTL), users can check the validity of the preset 
parameters and point table by performing test operation of the position board before creating a user 
program. 
The control monitor/graph function allows users to debug programs efficiently. 
 
(9) Forced stop function 
The batch forced stop is available for connected servo amplifiers by the forced stop input signal of the 
external input. 
 
(10) Easy application to the absolute position system 
(a) The MR-J4(W )- B series servo amplifiers and servo motors support the absolute position system. 
Absolute position system can be used by connecting the battery for absolute position system to the 
servo amplifier. 
 
(b) Once the home position has been established, the home position return operation is unnecessary at the 
system's power supply ON. 
 
(c) With the absolute position system, the data set method home position return is used to establish the 
home position. The wiring of proximity dog, etc. is unnecessary.