Mitsubishi Electronics MR-MC210 ユーザーズマニュアル
7 - 49
7. AUXILIARY FUNCTION
Setting
No. Name Initial
value
Setting
range
Remarks
0015
Sampling trigger 6
setting
setting
00000000h 00000000h
to 10041F01h
Same as the sampling trigger 1 setting.
0016
Sampling trigger 7
setting
setting
00000000h 00000000h
to 10041F01h
Same as the sampling trigger 1 setting.
0017
Sampling trigger 8
setting
setting
00000000h 00000000h
to 10041F01h
Same as the sampling trigger 1 setting.
0018
00000000h
0019 00000000h
001A 00000000h
001B 00000000h
001C 00000000h
001D 00000000h
001E 00000000h
001F 00000000h
0020
Sampling trigger value 1 00000000h 00000000h to
FFFFFFFFh
Set the threshold for trigger 1.
Note 1. Set the threshold in double word regardless of the size of
Note 1. Set the threshold in double word regardless of the size of
the data set in the sampling trigger 1 setting.
2. When the contents of trigger 1 are sampling bit
information, this setting is not used.
0021
Sampling trigger value 2 00000000h 00000000h to
FFFFFFFFh
Set the threshold for trigger 2.
The setting contents are the same as the sampling trigger value 1.
The setting contents are the same as the sampling trigger value 1.
0022
Sampling trigger value 3 00000000h 00000000h to
FFFFFFFFh
Set the threshold for trigger 3.
The setting contents are the same as the sampling trigger value 1.
The setting contents are the same as the sampling trigger value 1.
0023
Sampling trigger value 4 00000000h 00000000h to
FFFFFFFFh
Set the threshold for trigger 4.
The setting contents are the same as the sampling trigger value 1.
The setting contents are the same as the sampling trigger value 1.
0024
Sampling trigger value 5 00000000h 00000000h to
FFFFFFFFh
Set the threshold for trigger 5.
The setting contents are the same as the sampling trigger value 1.
The setting contents are the same as the sampling trigger value 1.
0025
Sampling trigger value 6 00000000h 00000000h to
FFFFFFFFh
Set the threshold for trigger 6.
The setting contents are the same as the sampling trigger value 1.
The setting contents are the same as the sampling trigger value 1.
0026
Sampling trigger value 7 00000000h 00000000h to
FFFFFFFFh
Set the threshold for trigger 7.
The setting contents are the same as the sampling trigger value 1.
The setting contents are the same as the sampling trigger value 1.
0027
Sampling trigger value 8 00000000h 00000000h to
FFFFFFFFh
Set the threshold for trigger 8
The setting contents are the same as the sampling trigger value 1.
The setting contents are the same as the sampling trigger value 1.
0028 For
manufacturer
setting
00000000h
0029 00000000h
002A 00000000h
002B 00000000h
002C 00000000h
002D 00000000h
002E 00000000h
002F 00000000h