7 - 89 
7. AUXILIARY FUNCTION 
 
(2) System Command/Status Data 
(a) System Commands 
 
Address Name 
Setting 
range 
Remarks 
01B0 
Reading of log data 
Page number 
1 to 256  Sets the page number for the log data area for logged data to be read to. 
Data for 16 events of log data are read for each page. 
Example. When the number of valid events is 345 events 
345/16   21
In other words, pages 1 to 22 are read. 
01B1  
 
(b) System status 
 
Address Name 
Output 
limits 
Remarks 
01F0 
Reading of log data 
Page number 
1 to 256  Stores the page number that was read. 
The details for the settings for the page number of the log data that was read 
using a system command are stored. 
01F1 
01F2 
Number of valid log data 
events 
0 to 4096  Stores the number of number of valid events stored in current log data. When 
the number of valid events reaches 4096 events the number of valid events 
becomes 4096. 
01F3