Mitsubishi Electronics MR-MC210 ユーザーズマニュアル

ページ / 658
 
 
7 - 104 
7. AUXILIARY FUNCTION 
 
(b) Details concerning system status bits 
 
Abbreviation Signal 
name 
Function 
details 
MINFC Machine 
type 
information (CCF) 
[Function] 
Shows that the controller connected is a position board. 
[Operation] 
<Conditions for turning on> 
Position board is connected. 
<Conditions for turning off> 
A controller other than position board is connected. 
AHINF 
Alarm history information  [Function] 
Shows that position board is alarm history compatible. 
[Operation] 
<Conditions for turning on> 
An alarm history compatible position board is connected. 
<Conditions for turning off> 
A position board that is not alarm history compatible is connected. 
ALHRF 
Alarm history read 
complete  
[Function] 
Notifies that reading of alarm history was completed normally. 
[Operation] 
<Conditions for turning on> 
Reading of alarm history is completed normally. 
<Conditions for turning off> 
Alarm history read command signal (ALHR) was turned off. 
ALHRE 
Alarm history read error 
[Function] 
Notifies that reading of alarm history was not completed normally. 
[Operation] 
<Conditions for turning on> 
Alarm history read command signal (ALHR) was turned on with an alarm history read 
page number set outside page number limits. 
<Conditions for turning off> 
Alarm history read command signal (ALHR) was turned off. 
ALHIF Alarm 
history 
initialization complete  
[Function] 
Notifies that alarm history initialization was completed normally. 
[Operation] 
<Conditions for turning on> 
Initialization of alarm history is completed normally. 
<Conditions for turning off> 
Initialization of data entered through turning the alarm history initialization command 
signal (ALHI) on. 
The alarm history initialization command signal (ALHI) was turned off. 
ALHIE Alarm 
history 
initialization error 
[Function] 
Notifies that alarm history initialization was not completed normally. 
[Operation] 
<Conditions for turning on> 
Alarm history initialization command signal (ALHI) was turned on with a value other 
than E15Ah set to the alarm history initialization ID. 
<Conditions for turning off> 