7 - 107
7. AUXILIARY FUNCTION
7.17.5 Alarm history initialization procedure
The procedure for initialization of parameters are as follows.
Yes
sscClearAlarmHistoryData function
End
No
Note. Set E15A to the alarm history initialization ID.
Turn off alarm history
initialization command (ALHR)
initialization command (ALHR)
Alarm history initialization ID
setting
setting
Turn on alarm history
initialization command (ALH)
initialization command (ALH)
Start
Alarm
history initialization
complete?
POINT
Do not turn off the power supply to the position board during initialization of
alarm history.
Alarm history data cannot be read during initialization of alarm history.
API LIBRARY
Use the sscClearAlarmHistoryData function to initialize alarm history.
7.17.6 List of system errors that do not apply to alarm history storage
System errors that do not apply to alarm history storage are shown below.
Error code
Content
E001 ROM
error
E002
RAM error 1
E003 Dual
port
memory
error
E004
RAM error 2
E006
SSCNET communication IC error 1
E007
SSCNET communication IC error 2
E008 Board
error
E1
CPU
error
EF01
System command code error