11 - 3 
11. PARAMETERS 
 
Parameter 
No. 
Symbol Name 
Initial 
Value
Units
Setting 
range 
Function 
000F *IFM0 
Interface 
mode 
option 0000h
 0000h 
to 0F0Fh
0
0
Interrupt output cycle
When interrupt by interface mode
is valid, set the cycle for which
the interrupt is output.
Interrupt output cycle:
Control cycle   (setting value+1)
Example: When interrupt output cycle
                is set to 1 and control cycle
                is 0.88ms, interrupt is output
                approximately every 1.77ms.
Command data update cycle
Set the cycle for which position
command is updated in interface mode.
Command data update cycle:
Control cycle   (setting value+1)
Example: When command data update
                cycle is set to 2 and control
                cycle is 0.88ms, position
                command is updated
                approximately every 2.66ms.
0010  
For manufacturer setting 
 
 
 
: : 
003F 0 
0040 LGS1 
Log 
acquiring 
selection 
(Note) 
0000h
 
0000h 
to 0001h
Set whether to acquire the log of the system when 
the log function is used. 
System (bit 0) 
  0: Not acquire  1: Acquire 
0041 LGS2 
Log 
acquiring 
selection 
(Note) 
0000h
 0000h 
to FFFFh
Set the axis number for which the log is to be 
acquired. 
Axis 1 (bit 0) to axis 16 (bit 15) 
  0: Not acquire  1: Acquire 
0042 LGS3 
Log 
acquiring 
selection 
(Note) 
0000h
 
0000h 
to FFFFh
Set the axis number for which the log is to be 
acquired. 
Axis 17 (bit 0) to axis 32 (bit 15) 
  0: Not acquire  1: Acquire 
0043  
For manufacturer setting 
0000h
 
 
 
0044 0000h
0045 0 
: : 
007F 0 
Note. When all the system parameters of the log acquiring selection (parameters No. 0040 to 0043) are set to 0000h (initial value), log 
for all axes and systems will be acquired.