Mitsubishi Electronics MR-MC210 ユーザーズマニュアル

ページ / 658
 
 
3 - 5 
3. INSTALLATION AND WIRING 
 
POINT 
 
• Migratable plasticizer is used for vinyl tape. Keep the MR-J3BUS M, and  
MR-J3BUS M-A cables away from vinyl tape because the optical 
characteristic may be affected. 
Optical cord
Cable
 
 
SSCNET  cable 
Cord 
Cable 
 
 
MR-J3BUS M 
 
 
 
 
MR-J3BUS M-A 
 
 
 
MR-J3BUS M-B 
 
 
 
: Normally, cable is not affected by plasticizer. 
: Phthalate ester plasticizer such as DBP and DOP may affect optical 
characteristic of cable. 
 
Generally, soft polyvinyl chloride (PVC), polyethylene resin (PE) and fluorine 
resin contain non-migratable plasticizer and they do not affect the optical 
characteristic of SSCNET  cable. However, some wire sheaths and cable 
ties, which contain migratable plasticizer (phthalate ester), may affect  
MR-J3BUS M and MR-J3BUS M-A cables (made of plastic). In addition, 
MR-J3BUS M-B cable (made of quartz glass) is not affected by plasticizer. 
 
• If the adhesion of solvent and oil to the cord part of SSCNET  cable may 
lower the optical characteristic and machine characteristic. If it is used such 
an environment, be sure to do the protection measures to the cord part.  
• When keeping the position board or servo amplifier, be sure to put on a cap 
to connector part so that a dirt should not adhere to the end of SSCNET  
connector. 
• SSCNET  connector to connect the SSCNET  cable is put a cap to protect 
light device inside connector from dust. For this reason, do not remove a cap 
until just before connecting SSCNET  cable. Then, when removing 
SSCNET  cable, make sure to put a cap. 
• Keep the cap and the tube for protecting light cord end of SSCNET  cable 
in a plastic bag with a zipper of SSCNET  cable to prevent them from 
becoming dirty. 
• When exchanging the position board or servo amplifier, make sure to put a 
cap on SSCNET  connector. When asking repair of position board or servo 
amplifier for some troubles, make also sure to put a cap on SSCNET  
connector. When the connector is not put a cap, the light device may be 
damaged at the transit. In this case, exchange and repair of light device is 
required.