APPENDIX 
 
Control cycle settings are imported during system startup (system command code: 000Ah), and cannot be 
changed during system running (system command code: 000Ah). 
 
(a) System parameters 
 
Parameter 
No. 
Abbreviation Name 
Function 
0001 *SYSOP1 
System 
option 
0
0
SSCNET communication method
Set the SSCNET communication
method.
0: SSCNET    /H (Not use)
1: SSCNET
Make sure to set "1: SSCNET    ".
(Note) SSCNET communication
method is shared in lines
1 and 2.
Control cycle setting
Set the control cycle
[When SSCNET communication
method is 1: SSCNET    ]
0: 0.88ms
1: 0.44ms
0002 *SYSOP2 
System 
option 
0
Axis No. assignment
Set 1 when validating axis No.
assignment.
When axis No. assignment is invalid,
axis No is automatically assigned.
0: Invalid
1: Valid
0
Consistency check selection at
system startup
Set whether to perform consistency
check for controlled axes setting at
system startup.
0: Valid
1: Invalid
 
(b) SSCNET communication method 
 
Address Name 
Description 
0008 
SSCNET communication method 
1: SSCNET  
2: SSCNET /H 
0009