11 - 2
11. PARAMETERS
11.1 System parameters
POINT
The settings for the parameters with a * mark at the front of the abbreviation
are validated when the system is restarted.
Parameter
No.
Symbol Name
Initial
Value
Units
Setting
range
Function
0001
*SYSOP1 System option 1
0000h
0000h
to 0002h
0
0
Set the control cycle
0: 0.88ms
1: 0.44ms
2: 0.22ms
SSCNET communication method
Set the SSCNET communication
method.
0: SSCNET /H
(Note) SSCNET communication
method is shared in lines
1 and 2.
0002
*SYSOP2 System option 2
0000h
0000h
to 1101h
0
Consistency check selection at
system startup
Set whether to perform consistency
check for controlled axes setting at
system startup.
0: Valid
1: Invalid
Control mode selection
Select the control mode.
0: Standard mode
1: Interface mode
system startup
Set whether to perform consistency
check for controlled axes setting at
system startup.
0: Valid
1: Invalid
Control mode selection
Select the control mode.
0: Standard mode
1: Interface mode
Axis No. assignment
Set 1 when validating axis No.
assignment.
When axis No. assignment is
invalid, axis Nos. are automatically
assigned.
0: Invalid
1: Valid
Set 1 when validating axis No.
assignment.
When axis No. assignment is
invalid, axis Nos. are automatically
assigned.
0: Invalid
1: Valid
0003
For manufacturer setting
0
0004 SITM
System
interrupt
conditions
0000h
0000h
to FFFFh
Set the interrupt conditions for the system.
0005
For manufacturer setting
0
0006 0
0007 0
0008 0
0009 0
0007 0
0008 0
0009 0
000A 0
000B 0
000C 0
000D 0
000E *EMID
000B 0
000C 0
000D 0
000E *EMID
External
forced
stop
disabled
0000h
0000h
to FFFFh
Disable the forced stop by EMI signal.
5AE1h
: Forced stop disabled
Other than 5AE1h : Forced stop enabled