Transition Networks DVP 5960 ユーザーズマニュアル

ページ / 4
Installation NOTES
To install the PS-CF-01 series media converter:
1. Connect host signal to PS-CF-01 media converter.
Locate or build twisted-pair cables that are compliant with
cable specifications (See page 7) and with male RJ-45 plug
connectors installed at both cable ends.
NOTE: Install TRANSITION Networks balun part number: 3-4554
between RJ-45 cable and Twinax connector.
Install balun at host Twinax connector.
•. Connect male RJ-45 plug connector at one end of twisted pair
cable to balun on host Twinax connector.
Connect male RJ-45 plug connector at other end of twisted
pair cable to female RJ-45 connector on PS-CF-01 media
converter.
2. Connect PS-CF-01 media converter near host to second PS-CF-01
media converter near terminal device*.
Locate or build fiber cable that conforms to cable
specifications (See page 7) and with male fiber connectors
installed at both ends. 
Connect one end of first fiber cable to PS-CF-01 media
converter TX connector.
Connect other end of that fiber cable to second PS-CF-01
media converter RX connector (or to PowerStar™ IV fiber SIC
card RX connector).
Connect one end of second fiber cable to PS-CF-01 media
converter RX connector.
Connect other end of that fiber cable to second PS-CF-01
media converter TX connector (or to PowerStar™ IV fiber SIC
card TX connector).
*Or optionally connect directly to PowerStar™ IV fiber SIC card. 
CABLE SPECIFICATIONS
The physical characteristics of the cable must meet or exceed the following: 
FIBER CABLE 
MULTIMODE
Fiber Optic Cable Recommended:
62.5 / 125 µm multimode fiber
Fiber Optic Transmitter Power:
min: -19.0 
dBm
max: -14.0 
dBm
Fiber Optic Receiver Sensitivity:
min: -32.5 
dBm
max: -14.0 
dBm
Wavelength:
850nM
Bit error rate:
10
-9
Maximum Cable Distance:
2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended:
9 µm singlemode fiber
Fiber Optic Transmitter Power:
min: -27.0 
dBm
max: -17.0 
dBm
Fiber Optic Receiver Sensitivity:
min: -32.5
dBm
max: -13.0 
dBm
Wavelength:
1300nM
Bit error rate:
10
-9
Maximum Cable Distance:
8 kilometers
TWISTED PAIR CABLE AND CONNECTOR 
Category 3 wire or better is required; category 5 wire is recommended. Either
shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO
NOT USE FLAT OR SILVER SATIN WIRE.
Category 3:
Gauge
24 to 22 AWG
Attenuation 
28 dB/1000’ @ 10 MHz
Differential Characteristic Impedance 
100 
Ω
±10% @ 10 MHz 
Category 5:
Gauge
24 to 22 AWG
Attenuation 
20 dB/1000’ @ 10 MHz
Differential Characteristic Impedance 
100 
Ω
±10% @ 10 MHz 
Minimum UTP/STP Cable Distance:
7.6 meters (25 feet)
Maximum UTP/STP Cable Distance:
762 meters (2500 feet
)
Connector:
RJ-45 connectors with active
pair pins 4 & 5. 
All cable connections to the PS-CF-01 MUST be
AT LEAST 7.6 meters (25 feet) in length.
PS-CF-01
3
4
5
6
RJ-45
connector
Straight Through Cable
3
4
5
6
RJ-45
connector
NOTE: The active pair in a twisted-pair
copper 5250-compliant network are pins
4 & 5. Use only dedicated wire pairs
(such as blue/white & white/blue,
orange/white & white/orange) for the
active pins.