HP (Hewlett-Packard) 3.1.X ユーザーズマニュアル

ページ / 307
Fabric Watch
178
Threshold Notification Fields Descriptions
The Fabric Watch Threshold Configuration Area Configuration fields are 
described in 
Table 42:  Threshold Configuration Area Configuration Field Descriptions 
Field
Description
Boundary 
Unit
Set or display the selected unit values used for the chosen 
area. Depending on the area of interest, this is figured in 
units of “downs, reconfigs, errors, changes, logins,” etc.
High
Set or display the number of high boundaries (the highest 
limit at which an element will not trigger an event) for the 
selected area. 
BufferSize
Set or display the threshold boundry buffer size of the 
selected area. 
TimeBase
Set or display the basic unit of time in which events are 
recorded for the selected area. The units available from the 
drop-down menu are: none, second, minute, hour, or day. 
Low
Set or display the number of low boundaries (the lowest limit 
at which an element will not trigger an event) for the selected 
area. 
Select Boundry Level Select either a default or custom setting for the boundry levels 
from the drop-down menu. The default values are shown in 
parenthesis. 
Alarm Setting
Alarm Notification 
Mechanisms
Select Alarm settings for Errorlog, SNMP, RAN, Portlog and 
Email to be active on the switch side.
Select Alarm Level
Select either a custom or default setting for the alarm level 
from the drop-down; this setting will be active on the switch 
side menu. 
Update Flash
Check box to update Flash Memory. From Web Tools, when 
you set new threshold values and click Apply, these new 
values are sent to the Fabric Watch daemon on the switch 
and activated at once. These values are not however saved in 
RAM and can be lost after a switch reboot. 
When you check the update flash box, the current set of 
threshold values will be committed to flash memory, which is 
persistent storage. Those values are then saved over a switch 
reboot.