Appendix A- 7
with the additional tuning for secure TX deviation and secure RX 
discriminator level tuning.
Transmit Deviation Balance 
(Compensation)
When tuning with a secure board installed, the coupling capacitor 
inside the RKN4035A Test Cable will cause rolloff of the low port 
modulation. To fix this, the cable should be dc coupled (“VOL” 
position) and an external coupling capacitor (1.3µF or larger) must be 
placed in series with the signal source input to the AC/DC MTR.
Follow the “Transmit Deviation Balance (Compensation)” 
procedure outlined in Section 5, except change step 3 as follows:
3. Set the RTX4005B Test Box meter selector switch to the “VOL” 
position, and connect the signal source to the AC/DC MTR port 
thru a 1.3µF capacitor. Inject an 80 Hz tone at 100mVrms thru this 
capacitor. Keep the ac voltmeter in parallel to the AC/DC MTR 
input to ensure the proper input signal level.
Secure TX Deviation
Transmit deviation balance (compensation) and transmit deviation 
limit adjustments should be completed before secure deviation is 
adjusted. Remember to use the new transmit deviation balance 
procedure outlined in the previous paragraphs before performing the 
following steps.
1. From the SERVICE menu, press F2 to select TRANSMITTER 
alignment.
2. Press F8 to select the SECURE TX DEV softpot.
3. Press F6 to key the radio on the test frequency. The screen will 
indicate that the radio is transmitting.
4. Measure the secure deviation on your service monitor.
5. Use the up/down arrow keys to adjust the secure deviation per 
Appendix Table 3.
6. Press F6 to dekey the radio. Press F8 to program the softpot value.
7. Press F10 to return to the TRANSMITTER menu.
Secure RX Discriminator 
Level
8. Set the RTX4005B Test Box meter selector switch to the “MX 
DISC” position, and connect an ac volt-meter (capable of 1mV 
resolution on a 2V scale) to the test box AC/DC meter port.
9. From the SERVICE menu, press F3 to select RECEIVER alignment.
10.Press F8 to select the SECURE DISCRIMINATOR LEVEL softpot. 
The screen will indicate the receive test frequency to be used.
11.Set the RF test generator to the receive test frequency. Set the RF 
Appendix A Table 3.  Secure Deviation
Channel Spacing (kHz)
Secure Deviation (kHz)
25 / 30
2.91 - 3.06
20 (VHF / UHF)
1.69 - 1.84
20 (821 - 824, 866 - 969)
1.69 - 1.84
12.5
N / A