Blomberg DV 17540 NBL00 ユーザーズマニュアル

ページ / 24
11 - EN
be placed on top of a washing machine, the 
approximate weight together may reach 397 
lbs (180 kg) when they are full.  Therefore, 
the floor must be capable of carrying the load 
placed on it!
Adjusting the feet
In order to ensure that your 
appliance operates more 
silently and vibration-free, 
it must stand level and 
balanced on its feet.  The 
front feet of the appliance can be adjusted. 
Balance the appliance by adjusting the feet.
1. Loosen the feet by hand.
2. Adjust them until the appliance stands level 
and firmly.
C
Do not use any tools to loosen the 
adjustable feet. Otherwise, they may be 
damaged.
C
Never unscrew the adjustable feet from their 
housings.
2 plastic pieces supplied together with the 
Operating Instructions prevent your appliance 
from slipping on wet and slippery surfaces. To 
install these plastic parts:
1. Tilt the appliance backwards.
2. Fit the plastic parts to the front adjustable 
feet. Press on the plastic parts to fix them in 
their places.
3. Check the balance of the appliance again 
and readjust the adjustable feet if necessary.
Ventilation duct and 
connection 
Ventilation duct ensures exhaust of air from 
inside the appliance.
The vented dryer has 1 air outlet.
A
Only rigid or flexible metal duct should be 
used for exhausting, unless the appliance has 
been checked for use with nonmetallic duct 
or the duct has been checked and found 
acceptable for use with clothes dryers. 
• In Canada, the diameter of the duct to be 
used should be 4” (102 mm). In United States, 
the regulation for the required exhaust duct 
diameter must be followed. 
Maximum duct length is given in the table 
below:
Metal rigid duct
Maximum length
21 ft (6.5 m) + 2 elbows
To connect a ventilation duct;
1.Connect the air outlet metal duct to the 
spacer by turning it counter-clockwise.
2.Make the duct passages as shown the 
picture below.
C
Exhaust of humid air from the dryer into 
the room is to be avoided. It may damage the 
walls and furniture in the room.
C
The ventilation duct can be routed outdoors 
via a window or it can be connected to the air 
outlet in a bathroom.
C
Air outlet duct must be extended directly 
outdoors. There must be a limited number of