Electrical Requirements
M414905
42
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To Connect Electrical Service To 
The Tumbler
The following steps outline the procedure for 
connecting the electrical service to the tumbler.
NOTE: The wiring diagram is located in the 
junction or contactor box.
1. Install a circuit breaker as close to the tumbler as 
possible. If more than one tumbler is being 
installed, a disconnect switch or circuit breaker 
should be provided for each. This will make it 
possible to disconnect each tumbler for 
maintenance purposes. 
2. Connect the conduit-encased leads to the disconnect 
switch, or circuit breaker. Connect the wire leads 
to the appropriate labeled terminal on the terminal 
block. The ground wire must be connected to the 
ground connection as shown in Figure 21
3. Check the electrical service phase sequence 
(three phase only) as follows:
a. Energize the electrical service (on reversing 
tumblers, ensure nonreversing is selected) and 
momentarily start the tumbler. Check the 
direction of the cylinder rotation. If the 
cylinder rotates clockwise (viewed from the 
front), the phase sequence is correct. If the 
cylinder rotates counterclockwise, proceed 
with step b.
NOTE:When viewed from the front, the 
fan should rotate clockwise on 50 and 75 
Pound models and counterclockwise on 
F75 models.
b. Disconnect and reverse any two service leads 
on the terminal block.