Alliance Laundry Systems TMB795C ユーザーズマニュアル

ページ / 63
Adjustments
M414905
56
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Airflow Switch 
Gas and Electric Tumblers
The airflow switch (located on the rear of tumbler, 
Figure 26) is set at the factory for proper operation. 
However, if there is a problem with the switch, it 
should be adjusted as follows:
Confirm exhaust duct and make-up air vents are 
properly sized and not obstructed. Refer to 
Make-Up Air and Venting sections.
Confirm lint screen is clean and access panels are 
in place.
Check operation of airflow switch and adjust as 
follows:
NOTE: Steam models do not have an airflow 
switch. 
The airflow switch operation is controlled by the 
counterweight position in the shaft. Moving the 
counterweight either increases or decreases airflow 
switch sensitivity. The counterweight should be 
adjusted so the disc moves away from the cabinet 
when the lint panel is opened 1.5 inches (38.1 mm) with 
a full load. Adjust the airflow switch as follows:
1. Load the tumbler. This adjustment is much faster 
to make with one person opening lint panel in 
front and another adjusting the counterweight in 
the rear of tumbler.
2. Temporarily tape down the lint panel safety 
switch located behind the upper right corner of 
the lint panel.
3. Start the tumbler. Open the lint panel 1.5 inches 
(38.1 mm). The airflow disc should move away 
from the cabinet, opening the switch contacts and 
shutting off the heat system. This indicates 
proper operation and proper adjustment.
4. If switch is not opening as described in step 3, it 
should be adjusted so it is MORE sensitive. 
Depress the spring clip and move counterweight 
toward disc. Retest by opening lint panel and 
continue moving counterweight toward disc until 
switch operates as described in step 3.
5. If switch opens BEFORE lint panel is opened the 
proper distance, step 3, it should be adjusted so it 
is LESS sensitive. Depress the spring clip and 
move counterweight away from the disc. Retest 
by opening lint panel and continue moving 
counterweight away from disc until switch 
operates as described in step 3.
IMPORTANT: Remove tape from lint panel switch.
WARNING
To reduce the risk of fire due to 
inadequate airflow, the airflow switch 
must be adjusted to operate per the 
instructions in this manual.
W674