Beko DRVS 73S ユーザーズマニュアル

ページ / 28
8
EN
Refer to the nearest Authorised Service 
Agent for installation of your product.
C
 Preparation of location and electrical 
installation for the product is under 
customer’s responsibility.
B
 Installation and electrical connections 
must be carried out by a qualified 
personnel.
A
 Prior to installation, visually check if 
the product has any defects on it. If 
so, do not have it installed. Damaged 
products will cause risks for your 
safety.
Appropriate installation 
location
•  Install the product in an environment 
which has no risk of freezing and is in a 
stable and level position.
•  Operate your product in a well 
ventilated, dust-free environment.
•  Do not block the air ducts in front of 
and under the product with materials 
such as long pile rugs and cupboard 
plinths. 
•  Do not place your product on a long 
pile rug or on similar surfaces.
•  Do not install the product behind a 
door with a lock, sliding door or a 
hinged door which can strike the 
product.
•  Once the product is installed, it should 
stay at the same place where its 
connections have been made. When 
installing the product, make sure 
that the rear wall of it does not touch 
anywhere (tap, socket, etc.) and also 
pay attention to install the product at a 
place where it will stay permanently.
B
Do not place the product on top of the 
power cable.
•  Keep at least 1.5 cm distance to walls 
of other furniture.
Under
 
Counter
 
Installation
•  Leave at least 3 cm of space between 
the side and rear walls of the machine 
and the walls of the counter/cupboard 
when installing your machine under a 
counter or in a cupboard. Never use 
the tumble dryer without top plate. 
Ventilation hose and 
connection (for products 
equipped with an outlet vent)
Ventilation hose assures exhausting of the 
air from inside the machine.
Vented dryer has 1 air outlet.
Stainless sheet metal or aluminum pipes 
can be used instead of the hose. The 
diameter of the pipe to be used should 
be minimum 10 cm.
Maximum hose and pipe lengths are 
given in the table below.
Hose
Pipe
Maximum length
4 m
5 m
1 elbow 45°
-1.0 m
-0.3 m
1 elbow 90°
-1.8 m
-0.6 m
1 elbow 90° short
-2.7 m
1 wall passage
-2.0 m
-2.0 m
C  Each elbow and other passages 
should be subtracted from the above 
maximum length.
To connect a ventilation hose;
1.  Connect the air outlet hose to the 
hose spacer piece by turning it anti-
clockwise.
2.  Make the hose passages as shown 
below.
C  Exhaust of humid air from the dryer 
into the room is inconvenient. It may 
damage the walls and furniture in the 
room.
C  The ventilation hose can be routed 
outdoors via a window or it can be 
connected to an air outlet in the wall 
(see diagram below).
C  Air outlet hose must be extended 
directly to the outdoors. There must 
be a small number of elbows as not to 
hinder air ventilation.
C  To prevent water accumulation in the 
hose, make sure that it is not folded on 
the floor.
3
  Installation