Sterling 882.00294.00 ユーザーズマニュアル

ページ / 63
 
 
Alarm Message 
Cause 
Corrective Action 
Dryer Status 
Check the pressure setting 
of the filter pressure 
differential switch against the 
print. Adjust accordingly. 
DIRTY FILTER 
 
The filter pressure 
differential switch has 
tripped. 
 
Check the filter pressure 
differential switch to make 
sure it is functioning. 
Replace is necessary. 
- Dryer Normal : 
- Process blower ON. 
- Process heaters ON. 
- Regen heaters ON. 
- Alarm Message ON. 
- Alarm horn is OFF. 
 
VALVE MOTOR 
FAIL 
 
The limit switch on the 
valve may not have 
been wired correctly. 
 
The switch is indicating the 
incorrect desiccant tank is in 
regeneration. Check the 
wiring of the switch against 
the wiring diagram. Make 
sure all the wire connections 
are tight. 
- Dryer Shuts Down : 
- Process blower OFF. 
- Process heaters OFF. 
- Regen heaters OFF. 
- Alarm Message ON. 
- Alarm horn is ON. 
 
The return air temperature 
thermocouple is not 
connected to the 
temperature controller. Make 
sure the connections are 
correct and tight. 
P RETURN 
SENSOR FAIL 
 
The return air 
temperature 
thermocouple is open 
or failed. 
 
The return air temperature 
thermocouple is damaged. 
Replace the thermocouple. 
- Dryer Normal : 
- Process blower ON. 
- Process heaters ON. 
- Regen heaters ON. 
- Alarm Message ON. 
- Alarm horn is OFF. 
 
Make sure the process air 
filter is clean. Clean or 
replace if necessary. 
Make sure all the hose 
connections are tight. 
The process heater 
contactor has failed in the 
closed position. Check 
heater contactor, replace if 
necessary. 
PROCESS 
TEMP SAFETY 
 
The high temperature 
snap switch of the 
process heater box 
has tripped. 
 
Check the high temperature 
snap switch, replace if 
necessary. 
- Dryer Shuts Down : 
- Process blower OFF. 
- Process heaters OFF. 
- Regen heaters OFF. 
- Alarm Message ON. 
- Alarm horn is ON. 
 
Make sure the process air 
filter is clean. Clean or 
replace if necessary. 
Make sure all the hose 
connections are tight. 
The Regeneration heater 
contactor has failed in the 
closed position. Check 
heater contactor, replace if 
necessary. 
REGEN TEMP 
SAFETY 
 
The high temperature 
snap switch on of the 
regeneration heater 
boxes has tripped 
 
Check the high temperature 
snap switches, replace if 
necessary. 
- Dryer Shuts Down : 
- Process blower OFF. 
- Process heaters OFF. 
- Regen heaters OFF. 
- Alarm Message ON. 
- Alarm horn is ON. 
 
 
Portable Drying/Conveying Systems 
Chapter 6:  Troubleshooting 
53 of 63