3.  No other fuel burning appliance shall be installed in the same closet as the gas 
dryer. 
4.  Refer to the images on this page to ensure the installation provides the 
minimum amount of clearance required for ventilation. 
5.  When installing the dryer in a closet with a door, a minimum of 120 square 
inches (774.2 square cm) of ventilation in the door is required. Openings must 
be equally divided at the top and bottom of the door and airflow must be 
unobstructed. A louvered door with equivalent air openings for the length of 
the door is acceptable. 
1.  Dryer MUST be exhausted outside (outdoors, not beneath the manufactured 
home) using metal ducting that will not support combustion. Metal ducting must 
be 4 inch (10.16 cm) in diameter with no obstructions. Rigid metal duct  
is preferred. 
2.  If dryer is exhausted through the floor and area beneath the manufactured 
home is enclosed, the exhaust system MUST terminate outside the enclosure 
with the termination securely fastened to the mobile home structure. 
3.  When installing a gas dryer into a manufactured home, a provision must be 
made for outside make up air. This provision is to be not less than twice the 
area of the dryer exhaust outlet. 
4.  This dryer MUST be fastened to the floor using. Manufactured Home 
Installation Kit. Follow the instructions supplied with the kit. 
5.  Refer to previous sections for other important venting requirements. 
6.  Installation must conform to current Manufactured Home Construction & Safety 
Standard (which is a Federal Regulation Title 24 CFR-Part 32-80) or when 
such standard is not applicable, with American National Standard for Mobile 
Homes. In Canada, the CSA Z240 is applicable.