GAS DRYER POWER HOOKUP
Gas Supply Requirements
Gas Type
Natural gas:
This dryer is equipped for use with Natural gas. It is design-certified 
by CSA International for LP (propane or butane) gases with 
appropriate conversion.
Your dryer must have the correct burner for the type of gas in 
your home. Burner information is located on the rating plate in 
the door well of your dryer. If this information does not agree 
with the type of gas available, contact your dealer or call the 
phone numbers referenced in the “Assistance or Service” 
section.  
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different gas 
without consulting your gas company.
Gas supply line
Must include 1/8" NPT minimum plugged tapping accessible 
 
for test gauge connection, immediately upstream of the gas 
connection to the dryer. See illustration.
1/2" IPS pipe is recommended.
3/8" approved aluminum or copper tubing is acceptable for 
lengths under 20 ft (6.1 m) if local codes and gas supplier 
permit.
If you are using Natural gas, do not use copper tubing.
Lengths over 20 ft (6.1 m) should use larger tubing and a 
different size adapter fitting.
If your dryer has been converted to use LP gas, 3/8" LP 
compatible copper tubing can be used. If the total length of the 
supply line is more than 20 ft (6.1 m), use larger pipe. 
NOTE: Pipe-joint compounds that resist the action of LP gas 
must be used. Do not use TEFLON
®†
®TEFLON  is a registered trademark of E.I. Du Pont De Nemours and Company.
 tape.
Must include a shutoff valve:
In the U.S.A.:
An individual manual shutoff valve must be installed within 
 
six (6) feet (1.8 m) of the dryer in accordance with the National 
Fuel Gas Code, ANSI Z223.1. 
In Canada:
An individual manual shutoff valve must be installed within 
 
six (6) feet (1.8 m) of the dryer in accordance with the B149.1, 
Natural Gas and Propane Installation Code. 
The location should be easy to reach for opening and closing.  
A
B
E
D
C
A. 3/8" flexible gas connector
B. 3/8" pipe to flare adapter 
fitting
C. 1/8"
 
NPT minimum 
plugged tapping
D. 1/2" NPT gas supply line
E. Gas shutoff valve
Gas supply connection requirements
Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting 
between the flexible gas connector and the dryer gas pipe, as 
needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON
®†
 tape.
This dryer must be connected to the gas supply line with a listed 
flexible gas connector that complies with the standard for 
connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
Burner input requirements
Elevations above 10,000 ft (3,048 m):
When installed above 10,000 ft (3,048 m) a 4% reduction of the 
burner Btu rating shown on the model/serial number plate is 
required for each 1,000 ft (305 m) increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping 
system during pressure testing at pressures greater than 1/2 psi.