Amana YKEHS01P ユーザーズマニュアル

ページ / 72
9
Electrical Connection - U.S.A. Only
Power Supply Cord
1. Disconnect power.
2. Remove the hold-down screw and terminal block cover. 
 Direct Wire
3. Assemble a 
³⁄₄ in. (1.9 cm) UL listed strain relief (UL marking 
on strain relief) into the hole below the terminal block 
opening. Tighten strain relief screws just enough to hold the 
two clamp sections together. Put power supply cord through 
the strain relief. The strain relief should have a tight fit with the 
dryer cabinet and be in a horizontal position.
4. Now complete installation following instructions for your type 
of electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
    1. Neutral grounding wire (green/yellow)
2. External ground conductor screw
3. Center, silver-colored terminal block screw
4. Terminal block cover and hold-down screw
Fire Hazard 
Use a new UL listed 30 amp power 
supply cord. 
Use a UL listed strain relief. 
Disconnect power before making electrical 
connections.
Connect neutral wire (white or center wire) to 
center terminal (silver). 
Ground wire (green or bare wire) must be 
connected to green ground connector. 
Connect remaining 2 supply wires to remaining 
2 terminals (gold). 
Securely tighten all electrical connections. 
Failure to do so can result in death, fire, or 
electrical shock.
1
2
3
4
Fire Hazard 
Use 10 gauge solid copper wire.
Use a UL listed strain relief. 
Disconnect power before making electrical 
connections.
Connect neutral wire (white or center wire) to 
center terminal (silver). 
Ground wire (green or bare wire) must be 
connected to green ground connector. 
Connect remaining 2 supply wires to remaining 
2 terminals (gold). 
Securely tighten all electrical connections. 
Failure to do so can result in death, fire, or 
electrical shock.