Veo Pan and Tilt ユーザーズマニュアル

ページ / 95
Network Camera User’s Guide 
 77/95 
Appendix B: Alarm I/O Connector 
Interfacing to the External I/O   
Some features of the Network Camera can be activated by an external sensor that 
senses physical changes in the area Network Camera is monitoring. These changes can 
include intrusion detection or certain physical change in the monitored area. For 
examples, the external sensor can be a door switch or an infrared motion detector. 
These devices are customer provided, and are available from dealers who carry 
surveillance and security products. Electrically, they must be able to provide a 
momentary contact closure.   
This Network Camera provides a general I/O terminal block with two digital inputs and 
two outputs for device control. Pin 7 and 8 can be connected to an external sensor 1. Pin 
7 and 6 can be connected to an external sensor 2. Both of the inputs, the voltage will be 
monitored from the initial state ‘LOW’. The relay switch of pin 3, 4 and 5 can be used to 
turn on or off the external device 1. The relay switch of pin 1 and pin 2 can be used to 
turn on or off the external device 2. External Inputs/Outputs are working independently. 
 
 
 
 
 
Pin 
Function 
Alarm Output #2 (NO) 
Alarm Output #2 (COM). Max 24VDC, 1A 
Alarm Output #1 (NO) 
Alarm Output #1 (COM) 
Alarm Output #1 (NC). Max 24VDC, 1A 
Alarm Input #2 (A). Max 24VDC, 12mA 
7 Alarm 
Input 
#1/2 
(K).