Panasonic WV-CLR920A ユーザーズマニュアル

ページ / 50
RS-485 Setting
Follow the procedures as below.
1. Slide the panel to the left until it locks.
2. Set RS-485 Termination Switch to RS485 LINE
TERM for the furthermost camera from the RS232C/
RS485 converter and Hi-Z for the other camera.
Initial factory setting is RS485 LINE TERM.
3. Select protocol by sliding triple full duplex/half
duplex selection switches simultaneously.
Initial factory settings are 4-line.
Notes:
• BP stands for Bit Position.
• Daisy chain connection is not available for full
duplex.
Switch 
Position
-16-
● Internal Diagram
T (B)
T (A)
R (B)
R (A)
GND
T (B)
T (A)
R (B)
R (A)
GND
Data Transmission
Data Reception
Data Transmission
Data Reception
RS485 Terminal
Control data is transmitted and received to and from
other peripherals.
Notes:
• Shielded, two twisted pairs cable
• Low impedance
• Wire gauge size is thicker than AWG#22
(0.33 mm
2
)
<Half duplex>
<Full duplex>
RS-485 Termination Switch (BP 1)
Function
RS485 LINE TERM
Termination ON
Hi-Z
Hi-Z
BP 2
BP 3
BP 4
Function
Right
Right
Right
Half duplex (2-line)
Left
Left
Left
Full duplex (4-line)
Switch 
Position
BP1
BP2
BP3
BP4