6.3
Input and Output Signals
6.3.1
Input and Output Signals
(1) Input signals to the printer
• DATA
: 8-bit parallel signal (Active High)
• STROBE
: Strobe signal to read the 8-bit data (Active Low)
• RESET
: Signal to reset the entire printer (Active Low); 1 ms or more
(2) Output signals from the printer
• ACK
: 8-bit data request signal.
A pulse signal to be output at the end of the BUSY signal
(Active Low)
• BUSY
: Signal to indicate that the printer is busy.
Input new data when it is "Low." (Active
High)
• FAULT
: Turned to "Low" when the printer has an alarm.
At this time, all the control circuits
in the printer stop. (Active Low)
• PE
: Output if the printing paper has run out or is running out. (Active High)
• Drawer Switch Output:
When connecting a drawer, turned to "High" if the switch is open. Turned to "Low" if
the switch is closed.
(3) Power source and the related
• GND
: Common ground for the circuits