Zebra Technologies radio frequency identification (rfid) ユーザーズマニュアル
137
SGD Commands for RFID
rfid.reader_1.power.read
11/14/2008
RFID Programming Guide
58978L-008 Rev. A
rfid.reader_1.power.read
Description This command sets or gets the RFID reader power level for reading RFID tags.
Type getvar; setvar
This table identifies the command for this format:
Note •
This parameter is ignored on the R110Xi HF printer because read and write powers
cannot be specified separately. See rfid.reader_1.power.single_power
to set the
power level for the R110Xi HF printer.
Commands
Details
getvar
This command instructs the printer to respond with the reader’s current
read power level.
read power level.
Format: ! U1 getvar "rfid.reader_1.power.read"
setvar
This command instructs the printer to set the read power level on the RFID
reader.
reader.
Format: ! U1 setvar "rfid.reader_1.power.read"
"value"
"value"
Note •
On some printers, the options vary based on the reader.
Check the printer configuration label for the RFID_HW_VER line
or perform the
or perform the
) to determine the reader type.
Example •
This setvar example sets the reader to high power for reading RFID tags.
! U1 setvar "
rfid.reader_1.power.read
" "high"
When the setvar value is set to "high", the getvar result is "high".
Printer
Firmware Version
Selections
Default
high,
medium,
low
0–30
up,
down
RXi
R60.15.8Z and earlier
X
—
—
low
R60.16.4Z
X
X
—
low
R60.16.5Z and later (M4xxx…x reader)
X
X
—
low
R60.16.5Z and later (M5xxx…x reader)
—
X
X
16
R4Mplus
SP994P, SP999F, SP1027F, SP1056E,
SP1082F, and earlier
SP1082F, and earlier
X
—
—
low
SP994Q, SP999G, SP1027G, SP1056F,
SP1082G, and later
SP1082G, and later
X
X
—
low
R110PAX4
R62.15.8Z and earlier
X
—
—
low
R62.16.4Z and later
X
X
—
low
R63.15.8Z and earlier
X
—
—
low
R63.16.4Z and later
X
X
—
low
RZx00
all versions
—
X
X
16
RP4T
all versions
—
X
X
16