Zebra Technologies radio frequency identification (rfid) ユーザーズマニュアル

ページ / 162
RFID Applicator Signals
Timing Diagrams for RFID
150
58978L-008 Rev. A
RFID Programming Guide
11/14/2008
Timing Diagrams for RFID
The following timing diagrams show how applicator signals function while an RFID label is 
printing and being programmed in Mode 1. For more information about Single and Double 
signal modes, see 
.
Single Signal Mode
 show the applicator signals for label formats using programming 
positions other than zero.
Figure 9 • Single Signal Mode, Good RFID Tag
Figure 10 • Single Signal Mode, Bad RFID Tag
Start Print
(pin 3)
Data Ready
(pin 14)
End Print
(pin 11)
Void
(pin 15)
1
3
4
5
2
1
Label ready for printing.
2
After receiving start print signal, begin printing label.
3
When program position is reached, pause and encode RFID tag.
4
Check void signal (high means good tag).
5
Print label.
Start Print
(pin 3)
Data Ready
(pin 14)
End Print
(pin 11)
Void
(pin 15)
1
3
4
5
6
2
1
Label ready for printing.
2
After receiving start print signal, begin printing label.
3
When program position is reached, pause and encode RFID tag.
4
Check void signal (low means bad tag).
5
Print void label (if applicable).
6
Discard bad label. Data Ready stays low if format to be retried on next label.