Notes on continuous flash operation (in close-up flash operation (using cords))
Max. number of continuous firings
Synchronization during continuous flash operation
It is possible to take up to the number of frames during continuous operation as 
shown in the table below. 
SB-R200’s maximum number of frames during continuous flash 
operation (at six frames per sec.)
Flash mode
Max. number of continuous 
firings (at 6 frames/sec.)
TTL auto flash
15
Manual flash (Flash output level: M1/1, M1/2)
Manual flash (Flash output level: M1/4 to M1/64)
30
Flash output level
1/8
1/16
1/32
1/64
Up to 4
Up to 8
Up to 16
Up to 30
WARNING
Do not exceed the maximum number of continuous 
firings
You should allow the Speedlight to cool off for at least 
10 minutes after the maximum number of continuous 
firings are performed as shown in the table below: