Sony DVW-790WS/790WSP ユーザーズマニュアル
8-5
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
8-4. ENC OUT Adjustment
8-4-1. ENC Level Adjustment
Preparation
OUTPUT/DCC switch (inside panel)
→
BARS
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
On the setup menu, adjust as follows.
PAGE
PAGE
: S23
*LEVEL 6
ITEM
: ENC Y SYNC
Spec.
: A = 40
±
1 IRE (NTSC)
A = 300
±
7 mV (PAL)
2.
On the setup menu, adjust as follows.
PAGE
: S40
*ENC ADJ.
ITEM
: SYNC START
Spec.
: B = 1.5
±
0.1
us (NTSC)
B = 1.65
±
0.1
us (PAL)
3.
On the setup menu, adjust as follows.
PAGE
: S40
*ENC ADJ.
ITEM
: SYNC STOP
Spec.
: C = 4.7
±
0.1
us
4.
Check as follows.
Spec.
: D = 2.3
±
0.1
us
5.
On the setup menu, adjust as follows.
PAGE
PAGE
: S23
*LEVEL 6
ITEM
: ENC Y SETUP
Spec.
: E = 7.5
±
0.5 IRE (NTSC)
E = 0
±
3 mV (PAL)
6.
On the setup menu, adjust as follows.
PAGE
PAGE
: S23
*LEVEL 6
ITEM
: ENC Y LEVEL
Spec.
: F = 100
±
2 IRE (NTSC)
F = 700
±
14 mV (PAL)
8-4. ENC OUT Adjustment
V BLANKING
D
50 %
F
E
PAL
F
E
NTSC
B
50%
20 IRE
C
A