8-5. TEST OUT Level Adjustment
Preparation
. OUTPUT/DCC switch (inside panel)
→
BARS
. On the setup menu, set as follows.
PAGE
: S23
*LEVEL 6
ITEM
: TEST OUT
→
R, G or B
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1.
On the setup menu, adjust as follows.
PAGE
PAGE
: S23
*LEVEL 6
ITEM
: RGB SYNC
Spec.
: A = 40
±
2 IRE (NTSC)
A = 300
±
14 mV (PAL)
2.
On the setup menu, adjust as follows.
PAGE
: S23
*LEVEL 6
ITEM
: RGB SETUP
Spec.
: B = 7.5
±
0.5 IRE (NTSC)
B = 0
±
3 mV (PAL)
3.
On the setup menu, adjust as follows.
PAGE
: S23
*LEVEL 6
ITEM
: RGB LEVEL
Spec.
: C = 100
±
2 IRE (NTSC)
C = 700
±
14 mV (PAL)
Setting After Adjustment
. On the setup menu, set as follows.
PAGE
: S23
*LEVEL 6
ITEM
: TEST OUT
→
ENC
8-6. Modulator Balance Adjustment
Preparation
. WHITE BAL switch (inside panel)
→
PRST
. OUTPUT/DCC switch (inside panel)
→
CAM/ON
. MENU ON/OFF/PAGE switch (inside panel)
→
OFF
Adjustment Procedure
1.
AUTO W/B BAL switch (front panel)
→
BLK
Hold this switch in BLK state untilthe message
“
“
_MOD BAL_” on the viewfinder is displayed .
2.
A few seconds later after releasing the switch, check
that the message “BLACK OK” is displayed on the
viewfinder.
that the message “BLACK OK” is displayed on the
viewfinder.
8-5. TEST OUT Level Adjustment
8-6. Modulator Balance Adjustment
8-6. Modulator Balance Adjustment
C
R
PAL
A
B
C
R
A
B
NTSC