Energizer ELCRV3 データシート

ページ / 1
Classification:
"Lithium Photo"
Chemical System:
Non-Aqueous Lithium
Designation:
Pending
Nominal Voltage:
3.0 Volts
Storage Temp:
-40°C to 60°C (-40°F to 140°F)
Operating Temp:
-40°C to 60°C (-40°F to 140°F)
Typical Capacity:
3000 mAh (to 2.0 volts)
(Rated at 200 mA at 21°C)
Typical Weight:
32 grams (1.1 oz.)
Typical Volume:
24 cubic centimeters (1.5 cubic inch)
Max Discharge:
2000 mA continuous (3000 mA pulse)
Typical Li Content:
1.25 grams (0.04 oz.)
UL Listed:
MH12454
Shipping: 
For complete details, please reference:
Special Provision A45 of the International
Air Transport Association Dangerous
Goods Regulations
49 CFR 173.185
Schedule
Drain
Drain
2.5V
2.0V
1.5V
(time)
(mA)
(mW)
(hours)
(hours)
(hours)
This datasheet contains typical information specific to products manufactured at the time of its publication. 
 ©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
---
2000
Important Notice
3
3.8
3.8
---
1000
2.8
2.9
7.7
8.5
8.5
15.8
United States:
Continuous
1000
---
1.8
Continuous
200
Typical Discharge Characteristics
Simulated Application Tests
15.7
Typical Performance at 21°C (70°F)
Specifications
mm (inches)
Global (except US):
ENERGIZER CRV3 
(ELCRV3)
Industry Standard Dimensions
Continuous
Continuous
This battery contains a Positive Temperature 
Coefficient (PTC) safety device to limit current 
during short circuit conditions.
Cutoff Voltage
---
14.7
1.5
2.0
2.5
3.0
3.5
0
4
8
12
16
V
o
lt
a
g
e
, CCV
Service, Hours
1000 mA
200 mA
Constant Current Discharge
at 21 C
1.5
2.0
2.5
3.0
3.5
0
2
4
6
8
10
V
o
lt
a
g
e
, CCV
Service, Hours
Constant Power Discharge
at 21°C
2000 mW
1000 mW
PRODUCT DATASHEET
1-800-383-7323 US/CAN
www.energizer.com
CR
V3
ø6.50 (0.256)
Typical
14.10 (0.555)
Typical
28.20 (1.110)
28.60 (1.126)
51.60 (2.031)
52.20 (2.055)
14.00 (0.551)
14.40 (0.567)
This Battery has Underwriters 
Laboratories component Recognition
Form No. EBC - 4210H
Page 1 of 1