MERLIN LEGEND Communications System Release 7.0
System Programming  
555-670-111  
Issue 1
April 1999
Programming with SPM 
2-50
Using SPM 
2
Considerations
2
Review the following items before you begin the restore procedure:
The system will be forced idle during a restore procedure.
You must have a backup file containing system programming before you 
use this procedure. 
.
Features that were not programmed when the backup file was created are 
reset to factory settings.
The data restored reflects the number of extensions and lines available on 
the system at the time the backup was created. The remaining extensions 
and lines are set to the factory settings that are initialized during a Restart 
(cold start).
Restore is terminated under the following conditions:
— If fewer boards are listed on the backup disk than on the control unit.
— If any real board is out of sequence with the boards listed on the 
backup disk.
— If phantom boards are not listed last.
— If the operating mode of the system being restored is Hybrid/PBX, 
but the control unit processor module has been modified to operate 
only in Key mode.
A successful restore is followed automatically by a Restart (cold start).
!
WARNING:
An unsuccessful or terminated restore results in a System Erase 
(frigid start). All calls are dropped. The system configuration is 
erased. All system programming is lost and the system returns to the 
factory settings. If the restore is being done remotely, the connection 
is dropped immediately. If this happens, attempt to reconnect to the 
control unit and immediately perform another restore. If this is not 
successful, programming must be restored on site.