Lucent Technologies 555-670-111 ユーザーズマニュアル

ページ / 1082
MERLIN LEGEND Communications System Release 7.0
System Programming  
555-670-111  
Issue 1
April 1999
Programming Procedures 
3-110
DS1 Facilities 
3
NOTE:
In Release 6.0 and later systems, you may order a point-to-point T1 circuit 
in order to provide amplification but not switching for a PRI tandem trunk 
that carries calls over long distances. PRI tandem trunks are preferable to 
T1 tandem trunks. Consult your Lucent Technologies representative for 
advice.
If the type is T1 and the type of channel emulation is tie trunk, you must specify 
whether the lines/trunks are TIE-PBX, Toll, or Switched 56 Data service. The valid 
settings are as follows:
TIE-PBX. Select when emulated tie trunks are used to connect to another 
communications system (such as PBX or Centrex). For releases prior to 
Release 6.0, the transmit/receive parameter is set to 0/4.
Toll. Select when emulated tie trunks are used for ASN services (such as 
Megacom‚ Megacom 800, or Software Defined Network). For releases 
prior to Release 6.0, the transmit/receive parameter is set to 0/6.
NOTE:
The parameters listed in the two above items are for releases prior to 
Release 6.0. In Release 6.0 and later systems, the transmit/receive 
gains are determined by the call constituents.
TIE – S56 Data. Select when emulated tie trunks are used for Switched 56 
Data Service. Switched 56 Data Service is available only in Release 4.0 
and later. The transmit/receive parameter is set to 0/0.
If the type is T1 and S56 Data Network Service is selected (available only in 
Release 4.0 and later), you must specify the following parameters: 
Direction. Specifies whether the trunk operates in one- or two-way 
direction. For one-way trunks, Outgoing Only or Incoming Only must also 
be specified.
Trunk Seizure Type. Trunk seizure type is programmed independently for 
incoming or outgoing directions. Select one of the following: Wink Start, 
Delay Start, or Automatic Start. 
Answer Supervision Time. The time in milliseconds the answer 
supervision signal must be present to be considered valid.
Disconnect Time. The time in milliseconds the disconnect signal must be 
present to be considered valid.
Dial Mode. Select either Rotary or Touch-Tone. Dial mode is set 
independently for incoming or outgoing directions (Inmode or Outmode).