Lucent Technologies 555-670-111 ユーザーズマニュアル

ページ / 1082
MERLIN LEGEND Communications System Release 7.0
System Programming  
555-670-111  
Issue 1
April 1999
Prior Releases: Features and Enhancements 
xlv
Release 4.0 Enhancements (March 1996) 
Voice Announce on Queued Call Console
0
The system manager can enable the fifth Call button on a QCC console (Hybrid/
PBX mode only) to announce a call on another user’s speakerphone (providing 
the destination telephone has a voice announce-capable SA button available). A 
QCC cannot receive voice-announced calls; they are received as ringing calls. 
The factory-set status for the fifth Call button is voice announce disabled.
Time-Based Option for
Overflow on Calling Group
0
Release 4.0 has added a 
time limit for calls in queue in addition to the previous 
number of calls limit. If the Overflow Threshold Time option is set to a valid 
number between 1 and 900 seconds, calls that remain in the calling group queue 
for the set time are sent to the overflow receiver. If the overflow threshold time is 
set to 0, overflow by time is turned off. The factory-set time limit is 0 seconds (off).
Single-Line Telephone Enhancements
0
The following changes enhance the performance of single-line telephones:
Disable Transfer. Through centralized telephone programming, the 
system manager can disable transfer by removing all but one SA or ICOM 
button from the extension.
No Transfer Return. When a handset bounces in its cradle, the system 
interprets this as a switchhook flash and attempts to transfer a call. When 
the transfer attempt period expires, the user’s telephone rings. Release 4.0 
eliminates this unintended ringing by disconnecting the call in situations 
where a switchhook flash is followed by an on-hook state and a dial tone is 
present.
Forward Disconnect. All ports on 008 OPT, 012, and 016 modules now 
send forward disconnect to all devices connected to them when forward 
disconnect is received from the central office. This enhancement prevents 
the 
trunk/line from being kept active when one end disconnects from the call. If 
an answering machine is connected to the port, it does not record silence, 
busy tones, or other useless messages. This operation is not 
programmable.
Seven-Digit Password for SPM
0
Release 4.0 has increased system security by requiring a 7-digit password for 
system managers or technicians who use System Programming and Maintenance 
(SPM) to perform programming or the Trunk Test procedure. This password is for 
use in addition to a remote access barrier code.