PROBLEM
CAUSES
SOLUTIONS
Rain sensor will not shut off system.
Incorrect sensor type wired directly into
Make sure sensor is microswitch type
sensor circuit.
such as Mini-Clik
®
.
The controller recognizes 48 stations
Make sure AC power is connected. Reset
all the time.
controller using method described on
page 31.
The controller does not respond
Controller does not recognize modules.
Turn off the power to the contr oller
to all the stations. Example, the
and remove the batter y. Check all
controller has 24 stations but the
module connections to the controller
display will only go to 16 stations.
Power the controller back up. The
microprocessor will recognize all modules.
The controller is only recognizing
Potential user pr ogramming er ror.
Be sure dial is in correct position.
eight stations when multiple
Total number of stations can be
modules are installed.
easily checked by placing dial in  SET
STATION RUN TIMES
 position and
pressing the back ar row.
Controller has display but will
Primar y power to controller incor rectly
Check and correct 110 or 220 volt
not activate zone valves.
wired. Controller receiving voltage too low
connection.
for valve operation.