Honeywell VISTA-50P ユーザーズマニュアル

ページ / 72
 
 
– 22 – 
Accessing Other Partitions (cont’d) 
Master Keypad Operation 
A "Master" keypad is one that reflects the status of the entire system 
(Partitions 1-8) on its display.  This is useful because it eliminates the need 
for a security officer in a building to have to "log-on" to various partitions 
from one partition’s keypad to find out where an alarm has occurred. 
A description of a typical display follows: 
SYSTEM 
1 2 3 4 5 6 7 8 
STATUS 
R R N N A T 
✴ B 
The status of each partition is directly below the partition number on the 
display. Possible status indications include: 
A = Armed Away 
S = Armed Stay 
M = Armed Maximum 
I = Armed Instant 
R = Ready 
N =  Not Ready 
B = Bypassed/Ready 
✴ = Alarm/Trouble 
To obtain more information regarding a particular partition, enter [
7] + 
[Partition No.] (i.e., 
74).  This will allow viewing only  of that partition.  In 
order to affect that partition, the user must log on with a code that has access 
to that partition.  Also, in order for a user of any partition to log onto the 
"Master" partition (Partition 9) to view the status of all partitions, and to 
perform any functions at the Master keypad, that user must have access to 
all partitions.  Otherwise, access will be denied. 
The following is an example of what would be displayed for a fault condition 
on Zone 002 (Loading Dock Window) on Partition 1 (Warehouse) when 
logging on from a keypad on Partition 9: 
WHSE DISARMED 
HIT 
✴ FOR FAULTS 
This is the normal display that appears at Partition 1’s keypad(s). Pressing 
will display: 
FAULT 002 LOADING 
DOCK WINDOW