This sets the MINIT and SREG strings for correct synchronous
operation with the MICROCOM 4232bis MODEM. The MODEM
configuration strings are set up as follows:
M2INIT=AT&M1 &D2 \GO \EO E1 &C1 \JO
SREG2=ATSO=1
ASYNC
This sets the MINIT and SREG strings for correct asynchronous
operation with the Trailblazer MODEM. The MODEM configuration
strings are set up as follows:
M2INIT=ATSO=1 &C1 &K3 E1 V1 &MO
SREG2=ATS7=60 S10=7 S37=7
~S50=255 ~S51=5 ~S52=1 ~S110=0 ~S104=0
ZYXEL (US Modems Only)
This sets M2INIT and SREG2 for the correct synchronous operation
with the ZYXEL modem. The modem configuration strings are set up
as follows:
M2INIT=AT&M1&D2&C1&H0
SREG2=ATS10=30 S0=1
USER=...
Available for user configuration
(Default, blank)
The USER string is for any extra commands that the user may need to
send to the modem in addition to the MINIT and SREG settings.
SEND
Send current modem configuration
This transmits the information contained in the MINIT, SREG and
USER strings to the MODEM.
Although this command can be issued from the command mode at any
time, it is also invoked at the termination of any call and when the
command mode is exited with the QUIT command.