Entry/Exit Delays
 
Exit Delay 
Exit delay begins immediately after arming the system, and gives you time to leave through the designated 
exit  door  without  setting  off  an  alarm.    A  slow  beeping  will  sound  throughout  the  exit  delay  period,  if 
programmed.  
 
Exit Alarms 
Exit Alarm Active         
To minimize false alarms sent to the alarm monitoring company, your system may have been programmed 
for this feature. Ask your installer if Exit Alarm is active for your system. 
    
 
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is faulted when 
the exit delay ends (e.g., exit door left open), the system sounds an alarm and starts the entry delay timer. If 
you  disarm  the  system  before  the  entry  delay  ends,  the  alarm  sound  stops  and  the  message  "CA"  is 
displayed on the keypad, along with a zone number indicating the faulted zone. No message is sent to the 
alarm monitoring company. To clear the exit alarm condition, the open zone must be made re-secured; to 
clear the display, enter your code plus OFF. 
 
If you do not disarm the system before the entry delay ends, and an entry/exit door or interior zone is still 
open, the alarm sound continues and an "exit alarm" message is sent to the alarm monitoring company. The 
message "EA" is displayed on the keypad, along with a zone number indicating the faulted zone. To stop 
the  alarm,  the  system  must  be  disarmed  (your  code  plus  OFF);  to  clear  the  display,  enter  your  code  plus 
OFF  a  second  time.   An exit alarm also results if an entry/exit door or interior zone is faulted within two 
minutes after the end of the exit delay. 
 
Entry Delay 
Entry Delays give you time to disarm the system when you re-enter through the designated entrance door. 
You must disarm the system before the entry delay period ends, or an alarm will occur. The keypad beeps 
during  the  entry  delay  period,  reminding  you  to  disarm  the  system.  There  are  two  entry  delays  (if 
programmed). The first is for your primary entrance and the second can be used for a secondary entrance, 
where a longer delay is required to walk to the keypad to disarm the system.  
 
You can also arm the system with no entry delay at all by using the 
NO DELAY
 key when arming. This can 
provide  greater  security  while  on  the  premises  or  while away for extended periods of time. See  ARMING 
THE SYSTEM
 section for procedure. 
 
See your installer for delay times programmed for your system. 
Exit Delay:                 00-99 seconds 
Entry Delay 1:            00-99 seconds 
Entry Delay 2:            00-99 seconds