First Alert 1 ユーザーズマニュアル

ページ / 48
– 25 –
 
86(5)81&7,216
Scheduling User Interface
 
 
To access the Scheduling User Interface enter: 
                           
 + 
FUNCTION
 
 +  
[64] 
 
Master user code or  
 
Installer Code 
 
The following entries will be sequentially prompted to the user. Note that all inputs are checked for validity 
upon  entry  and  all  invalid  entries  are  rejected.  Hitting  a  [*]  will  allow  the  entries  to  be  accepted  and 
advance  to  the  next  field.  Hitting  a  [#]  will  reject  the  entry  and  back  up  one  field.  Hitting  the  [#]  in  the 
“Schedule Number” screen will exit the schedule programming. 
 
NOTES: 1. 
During the schedule programming, if three minutes passes and no key was entered, the programming 
will be terminated and no values will be saved. Furthermore, if a zone is troubled while in schedule 
programming, the system will abort the programming mode and show the troubled zone, and any 
uncompleted program event will not be saved.  
 
2. 
It is not possible to enter the schedule programming mode from a wireless keypad (i.e. Ademco 5827) 
 
3. 
It is not possible to enter the schedule programming mode when either FC or CA is displayed on the 
display. 
 
Because  the  keypad  display  does  not  show  prompt  titles,  you  must  refer  to  these  instructions  while 
programming the system. The prompts are indicated by a number/letter combination. 
The prompts for option #64 are as follows: 
 
 
 
 
 
 
Schedule number------------- for selecting a schedule number (1-8) 
 
 
 
 
 
Event identifier--------------- for selecting a schedule action (0-5) 
 
 
 
A  b 
 
Begin time (hrs, am/pm)---- for selecting a schedule begin time (hour, am/pm) 
 
entry (00-12) 
 
 
 
 
 
Begin time (min)------------- for selecting a schedule begin time (minute) 
 
entry (00-59) 
 
 
 
 
 
Begin day--------------------- for selecting a schedule begin day (01-17) 
 
 
 
 
A  E   
End time (hrs, am/pm)------ for selecting a schedule end time (hour, am/pm) 
 
entry (00-12) 
 
 
 
E  : 
 
 
 
End time (min)--------------- for selecting a schedule end time (minute) 
 
entry (00-59) 
 
 
 
 
 
End day------------------------ for selecting a schedule end day (01-17) 
 
 
 
 
 
Device number--------------- for selecting a X-10 device number (1-8)