Testing the System (to be conducted weekly) 
 
Entering Test Mode 
The 
TEST
 key puts your system into the Test mode, which allows each protection point to be checked for 
proper operation. The keypad sounds a single beep every 45 seconds as a reminder that the system is in the 
Test mode.  
 
NOTE:  An alarm message will not be sent to your alarm monitoring company during the following tests. 
 
Disarm the system and close all protected windows, doors, etc. The “READY” indicator should be lit. 
 
Enter: 
                           
+ 
TEST  
key
 
 
Your user code
 
 
WATCH. All LCD segments will light for 3 seconds. 
 
LISTEN. 
The external sounder should sound for 2 seconds and then turn off. If the sounder does not sound, 
notify your service company.  
 
FAULT ZONES. 
Open each protected door and window in turn and listen for three beeps from the keypad, 
followed by the zone’s Voice Descriptor, if it is programmed. Identification of each faulted protection point 
should appear on the display. The display will clear when the door or window is closed. 
Walk in front of any interior motion detectors (if used) and listen for three beeps and/or voice descriptors, if 
programmed.  The  identification  of  the  detector  should  appear  on  the  display  when  it  is  activated,  and  its 
voice  descriptor  will  be  announced  (if  programmed).  The  display  will  clear  when  no  motion  is  detected. 
Note  that  if  wireless  motion  detectors  are  used,  there  is  a  3-minute  delay  between  activations.  This  is  to 
conserve battery life. 
To  test  all  smoke  detectors,  follow  the  manufacturer's  instructions.  The  identification  of  each  detector 
should appear on the display when each is activated. 
If  a  problem  is  experienced  with  any  protection  point  (no  confirming  sounds,  no  display),  notify  your 
service company. 
When all protection points have been checked and are intact (closed), there should be no zone identification 
numbers displayed on the keypad.  
 
Exit Test Mode 
When testing is completed, exit the TEST mode by entering: 
                           
+
OFF
 key.  
 
Your user code
 
 
NOTES:
  (1)  If the Test mode is inadvertently left active, it automatically turns off after 4 hours. 
 
(2)  Macros cannot be run from the Test mode.