2. STARTING UP THE MULTIPLE CPU SYSTEM 
This section describes a standard procedure to start up the Multiple CPU system.  
 
2.1 Startup Flow of the Multiple CPU System 
Multiple CPU system
Multiple CPU system design
Clarify control/function executed by each 
CPU.
Device application and assignment
Secure the refresh points continuously 
for automatic refresh of device data.
 • Refer to Section 3.1 for automatic refresh 
   function of device data.
Module select
Select modules to be used in the Multiple 
CPU system.
 • Refer to the "Q173CPU(N)/Q172CPU(N) User's  
   Manual" for module select.
Module install
Install the selected modules to the CPU 
base unit or extension base unit.
 • Refer to the "Q173CPU(N)/Q172CPU(N) User's 
   Manual" for install method or install position of  
   modules.
 
 • Refer to Section 2.1.4 of the "Q173CPU(N)/
   Q172CPU(N) User's Manual" for restrictions of      
   module install.
GX developer start
Start the GX Developer (Ver.6 or later).
 • Refer to the GX Developer manual for GX 
   Developer start.
Parameters, etc. create
Create the parameter setting such as 
Multiple CPU setting and control CPU 
setting, and the PLC programs.
 • Create the parameters for CPU No. 1 to 4 and   
   PLC programs.  
  
 • Refer to the "QCPU User's Manual" (Function
   Explanation/Program Fundamentals)" for PLC
   settings.        
Connect between the personal 
computer and PLC CPU
Connect between the personal computer 
running GX Developer and PLC CPU 
No.1 by RS-232/USB cable.
Connect between the personal 
computer and Motion CPU
Connect between the personal computer 
running SW6RN-GSV    P and Motion 
CPU by SSC I/F communication cable.
When the RS-232/USB cable is used to 
communicate with the Motion CPU, 
connect the cable to any one of the PLC 
CPU/Motion CPU in the Multiple CPU 
system.
Multiple CPU system power ON
Turn ON the power of Multiple CPU 
system in the following state of PLC 
CPU.
RUN/STOP switch : STOP
RESET/L.CLR switch : OFF
PLC CPU
Motion CPU
PLC CPU
Motion CPU
PLC CPU
1)