11   MOTION SFC PARAMETER 
 
 11 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
11. MOTION SFC PARAMETER 
Two different Motion SFC parameters are available: "task parameters" designed to 
control the tasks (normal task, event task, NMI task) and "program parameters" to be 
set per Motion SFC program. 
Their details are shown below. 
 
11.1 Task Definitions 
When to execute the Motion SFC program processing can be set only once in the 
program parameter per program. 
Roughly classified, there are the following three different tasks. 
 
Task type 
Contents 
Normal task 
Executes in motion main cycle (free time). 
Event task 
1. Executes in fixed cycle (0.88ms, 1.77ms, 3.55ms, 7.11ms, 14.2ms). 
2. Executes when the input set to the event task factor among external 
interrupts (16 points of QI60) turns on. 
3. Executes by an interrupt from the PLC CPU. 
NMI task 
Executes when the input set to the NMI task factor among external 
interrupts (16 points of QI60) turns on.