Mitsubishi Electronics Q173CPU(N) ユーザーズマニュアル

ページ / 472
 
 
 
13 - 4 
13   LIMIT SWITCH OUTPUT FUNCTION 
 
13.2 Limit Output Setting Data  
Limit output data list are shown below.  
Up to 32 points of output devices can be set.  
(The following items of No.1 to No.5 are set together as one point.)  
 
No. Item 
Setting 
range 
Fetch 
cycle 
Refresh 
cycle 
Remarks 
1  Output device 
Bit device (X, Y, M, L, B) 
— 
Operation 
cycle 
 
2 Watch 
data 
Motion control data/  
word device (D, W, #, absolute address)  
(16-bit integer type/32-bit integer type/  
64-bit floating-point type)  
 
ON Value  Word device (D, W, #)/constant (K, H) 
 
ON region 
setting 
OFF Value  Word device (D, W, #)/constant (K, H) 
 
Output enable/disable 
bit  
Bit device (X, Y, M, L, B, F, special relay)/ 
none (default) 
ON    : Enable  
OFF  : Disable  
None : Always 
enable 
5  Forced output bit  
Bit device (X, Y, M, L, B, F, special relay)/ 
none (default)  
Operation 
cycle 
— 
None : No forced  
outputs are 
always made 
(OFF status) 
 
(1)   Output device  
(a)   Set the bit device which outputs the ON/OFF signal toward the preset watch 
data.  
 
(b)   As the output device, the following devices can be used.  
 
Item 
Device No. setting range 
Input relay 
(Note-1)
 
X0 to X1FFF 
Output relay 
(Note-2)
 
Y0 to Y1FFF 
Internal relay 
(Note-3)
 
M0 to M8191 
Latch relay  
L0 to L8191 
Link relay 
B0 to B1FFF 
 
(Note-1) : PX is write-disabled and it cannot be used as the output device.  
For X, only the free No. of the input card non-loading can be used.  
(Note-2) : The real output device range (PY) is also included.  
(Note-3) : M2001 to M2032 cannot be used to the output device. 
Be careful because it affect a positioning operation, when the positioning 
dedicated devices are set.