Mitsubishi Electronics Q173CPU(N) ユーザーズマニュアル

ページ / 472
 
 
 
16 - 2 
16   COMMUNICATIONS VIA NETWORK 
 
16.1 Specifications of The Communications via Network 
(1)   Communications via network of the Motion CPU is possible by SW6RN-GSV P.  
 
(2)   Access range of the communications via network of the Motion CPU is an access 
range equivalent to Qn(H)CPU. (Refer to Section "16.2 Access Range of The 
Communications via Network".) 
 
(3)   By setting the routing parameter to the control CPU of the network module and the 
CPU which connected the peripheral devices in the network by 
MELSECNET/10(H) and Ethernet, it is possible to relay to 8 network points and 
communicate.  
 
(4)   Because  the Motion CPU cannot become the control CPU of the network module, 
there is not setting item of the network module and network parameter.  
However, when connecting with the CPU on the other network from the peripheral 
device which connected the Motion CPU, it needs to the setting of the routing 
parameter.  
 
(5)   It can operate by remote control the monitor or program editing of the Motion CPU 
via the intranet using the Ethernet module. 
 