18 - 1 
18   SERVO PARAMETER READING FUNCTION 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 18 
 
 
 
 
 
 
18.   SERVO PARAMETER READING FUNCTION
 
Refer to Section "1.3.4" for the correspondence version of the Motion CPU and the 
software.  
 
(1)   When the servo parameters are changed, the Motion CPU will be automatically 
read the servo parameters and reflected them to the servo parameter storage 
area in the Motion CPU. Therefore, an operation to read servo parameters is 
unnecessary in the following cases. 
(a)   The parameters are changed by auto tuning. 
 
POINT 
 
If the power supply of Motion CPU is turned off/reset or the power supply of servo 
amplifier is turned off immediately after change, it may not be reflected. 
 
 
(2)   After executing the servo parameter reading function, when it needs to reflect the 
servo parameters changed to the SW6RN-GSV P, read the servo parameters 
from the Motion CPU and save data. 
 
18.1 About The Servo Parameter Read Request Devices 
 
(1)   Set the axis No. of servo amplifier to read a parameter in the servo parameter 
read request axis No. (D9104) and turn the servo parameter read request flag 
(M9104) ON for reading of the servo parameter from servo amplifier. 
 
(2)   While the servo parameter reading flag (M9105) is turned on, the servo parameter 
read request flag does not become valid. Use this condition as an interlocks. 
 
(3)   Reading of servo parameter from servo amplifier becomes valid at the turning 
OFF to ON of the servo parameter read request flag. 
 
(4)   The servo parameter read request flag is not turned off automatically. Execute the 
device OFF processing by the user side. 
 
(5)  After executing the read function of the servo parameter from servo amplifier, 
when the servo parameter read request is executed toward the other axis, turn the 
servo parameter read request flag (M9104) OFF to ON, set the correspondence 
axis in the servo parameter read request axis No. (D9104) and turns the servo 
parameter read request flag (M9104) OFF to ON.   
 
(6)   After executing the read function of the servo parameter from servo amplifier, 
when the servo parameter read request is executed toward the same axis again, 
turn the servo parameter read request flag (M9104) ON to OFF, and turn the 
servo parameter read request flag (M9104) OFF to ON again.