Mitsubishi Electronics Q173CPU(N) ユーザーズマニュアル

ページ / 472
 
 
 
19 - 2 
19   ERROR CODE LISTS 
 
19.2 Motion SFC Error Code List 
Eight errors that occurred in the past during the Motion SFC control are stored in the 
"error history devices (#8000 to #8063)" of the motion registers. (Check by SW6RN-
GSV P). 
The "error codes" for the Motion SFC program are shown below. 
Refer to the "Q173CPU(N)/Q172CPU(N) Motion controller (SV13/SV22) Programming 
Manual (REAL MODE)"/ "Q173CPU(N)/Q172CPU(N) Motion controller (SV22) 
Programming Manual (VIRTUAL MODE )" for minor errors, major errors, servo errors 
and servo program setting errors. 
 
Table 19.1 Motion SFC dedicated devices (#8000 to #8063) 
Signal direction 
Device No. 
Signal name 
Status Command 
Refresh 
cycle 
Fetch 
cycle 
#8000 
to 
Seventh error information in past 
(Oldest error information) 
Motion SFC error history 
(8 errors) 
(64 points) 
No.
Signal name  
#8008 
to 
Sixth error information in past 
+0 
Error Motion SFC 
program No. 
1 Error 
type 
#8016 
to 
Fifth error information in past 
2  Error program No. 
#8024 
to 
Fourth error information in past 
Error block No. / 
Motion SFC list / 
Line No. / Axis No. 
4 Error 
code 
#8032 
to 
Third error information in past 
Year/ 
Month 
Day/ 
Hour 
#8040 
to 
Second error information in past 
Error 
occurrence 
time 
Minute/ 
Second
#8048 
to 
First error information in past 
#8056 
to 
#8063 
Latest error information  
 
 
— 
At error 
occur-
rence 
—