Mitsubishi Electronics Q173CPU(N) ユーザーズマニュアル

ページ / 472
 
 
 
1 - 74 
1   OVERVIEW 
 
1.4.4 Modules subject to installation restrictions 
 
(1)   Modules subject to installation restrictions in the Motion CPU are sown below. 
Use within the restrictions listed below. 
 
Maximum installable modules per CPU 
Description Model 
name
Q173CPU(N) Q172CPU(N) 
Servo external signals 
interface module 
Q172LX 
4 modules 
1 module 
Serial absolute synchronous 
interface module 
Q172EX 
(Note-1)
 
6 modules 
4 modules 
4 modules 
(Note-1)
 
(When using the incremental 
serial encoder.) 
3 modules 
(Note-1)
 
(When using the incremental 
serial encoder.) 
Manual pulse generator 
interface module 
Q173PX 
(Note-2)
 
1 module 
(When using only the Manual 
pulse generator.) 
1 module 
(When using only the Manual 
pulse generator.) 
Input module 
QX  
QX -S1 
Output module 
QY  
Input/output composite module 
QH  
QX Y  
Analogue input module 
(Note-3)
 
Q6 AD  
Q6 AD-  
Analogue output module 
(Note-3)
 
Q6 DA  
Q6 DA-  
Total 256 points 
Interrupt module 
QI60 
1 module 
(Note-1) : SV22 only. 
(Note-2) : When the Manual pulse generator and the serial encoder are used at the same time with the SV22, the 
Q173PX installed in the slot of the smallest number is used for manual pulse generator input. 
(Note-3) : A maximum of 4 modules, analogue input modules and analogue output modules, can be used. 
 
(2)   Modules controlled by a Motion CPU cannot be installed in the extension base 
unit QA1S6 B. Install them in the CPU base unit Q3 B or extension base unit 
Q6 B.  
 
(3)   A total of eight base units including one CPU base unit and seven extension base 
units can be used. However, the usable slots (number of modules) are limited to 
64 per system including vacant slots. If a module is installed in slot 65 or 
subsequent slot, an error (SP. UNIT LAY ERROR) will occur. Make sure all 
modules are installed in slots 1 to 64. (Even when the total number of slots 
provided by the CPU base unit and extension base units exceeds 65 (such as 
when six 12-slot base units are used), an error does not occur as long as the 
modules are installed within slots 1 to 64.)