Summary of Audible/Visual Notifications
Summary of Audible/Visual Notifications
Summary of Audible/Visual Notifications
Summary of Audible/Visual Notifications    
Fixed-Word Display Keypads 
 
SOUND CAUSE 
DISPLAY 
LOUD, 
INTERRUPTED* 
Keypad & Ext. 
FIRE ALARM  
FIRE is displayed; zone number of zone in 
alarm is displayed. If a fire alarm is manually 
activated, zone number 95 will be displayed.  
LOUD, 
CONTINUOUS* 
Keypad & Ext. 
BURGLARY/AUDIBLE  
EMERGENCY ALARM  
ALARM  is displayed. Zone number of zone in 
alarm is also displayed. 
ONE SHORT BEEP   
(not repeated)   
Keypad only 
 
 
a. SYSTEM DISARM  
b. SYSTEM ARMING ATTEMPT 
    WITH AN OPEN ZONE. 
c. BYPASS VERIFY  
 
a.  READY indicator light comes on.  
b. Number of the open protection zone displayed.
 
c. Zone numbers of the bypassed protection  
    zones are displayed (one beep is heard for  
    each zone displayed). Subsequently, BYPASS
    
is displayed. 
ONE SHORT BEEP 
(once every 40 secs)  
Keypad only 
a. SYSTEM IS IN TEST MODE 
b. LOW  BATTERY AT A 
    TRANSMITTER 
c. SYSTEM WILL AUTOARM 
WITHIN 10 MINUTES 
a. Opened zone numbers will appear. 
b. BAT displayed with zone number of  
     transmitter. 
c. No special display. 
TWO SHORT BEEPS  
Keypad only  
ARM AWAY or MAXIMUM 
AWAY is displayed. Red ARMED indicator is lit.
THREE SHORT 
BEEPS 
Keypad only 
a. ARM STAY, NIGHT-STAY, OR 
INSTANT   
 
b. ZONE OPENED WITH   
SYSTEM IN CHIME  MODE.   
a. STAY or INSTANT is displayed. Red  
    ARMED indicator  is lit. 
b. CHIME displayed; zone number of open  
     protection zone will be displayed if the [
∗]  
     key is pressed.  
RAPID BEEPING  
Keypad only 
a. TROUBLE  
 
b. MEMORY OF ALARM  
 
c. SYSTEM LOW BATTERY 
d. EXT. SOUNDER WIRING FAIL
e. LAST 10 SEC of EXIT DELAY 
a. CHECK displayed.  Zone number of troubled  
     protection zone is displayed. 
b. FIRE or ALARM is displayed; zone number 
    of zone in alarm is displayed 
c. BAT displayed with no zone ID number. 
d. CHECK 70 is displayed. 
e. No special display. 
SLOW BEEPING  
Keypad only 
a. EXIT DELAY WARNING  
b. ENTRY DELAY WARNING 
 
a. AWAY is displayed. 
b. Exceeding the entry delay time without   
    disarming causes alarm. 
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring