4 - 18 
4   INSTALLATION AND WIRING 
 
4.2 Connection and Disconnection of Cable  
4.2.1 SSCNET  cable 
(1)   Precautions for handling the SSCNET  cable 
• Do not stamp the SSCNET  cable. 
• When laying the SSCNET  cable, be sure to secure the minimum cable bend 
radius or more. If the bend radius is less than the minimum cable bend radius, it 
may cause malfunctions due to characteristic deterioration, wire breakage, etc.
 
• For connection and disconnection of SSCNET  cable, hold surely a tab of 
cable connector. 
 
Motion controller
CN1
 
 
(2)   Connection of SSCNET  cable 
• For connection of SSCNET  cable to the Motion controller, connect it to the 
SSCNET  connector CN1 of Motion controller while holding a tab of 
SSCNET  cable connector. Be sure to insert it until it clicks. 
• If the cord tip for the SSCNET  cable is dirty, optical transmission is interrupted 
and it may cause malfunctions. If it becomes dirty, wipe with a bonded textile, 
etc. Do not use solvent such as alcohol. 
 
(3)   Disconnection of SSCNET  cable 
• For disconnection of SSCNET  cable, pull out it while holding a tab of 
SSCNET  cable connector or the connector. 
• After disconnection of SSCNET  cable, be sure to put a cap (attached to 
Motion controller or servo amplifier) to the Motion controller and servo amplifier. 
• For SSCNET  cable, attach the tube for protection optical cord's end face on 
the end of connector.