Mitsubishi Electronics Q-Series Q170MSCPU ユーザーズマニュアル
4 - 31
4 INSTALLATION AND WIRING
4.3.3 Wiring of connector
Specialised tools are not required for wiring the 24VDC power supply connector and
forced stop input connector because plugs with spring connection are used.
forced stop input connector because plugs with spring connection are used.
(1) Applicable wire size and wire fabrication
(a) Applicable wire size
The applicable wire size for 24VDC power supply connector and forced stop
input connector are shown below.
input connector are shown below.
Connector
Type
Applicable wire size
24VDC power supply connector
FKC-2.5/3-ST-5.08
0.3 t0 2.5mm
2
(AWG12 to AWG22)
Forced stop input connector
FK-MCP1.5/3-ST-3.81
0.3 t0 1.5mm
2
(AWG16 to AWG22)
(b) Wire fabrication
Strip the wire according to stripped length indicated in the figure below.
Slide the sheath off the wire and gently twist and straighten the strands.
When using the wire, be careful not to short with stray strands entering the
neighbouring poles. Do not use solder on the wire's core as this may lead to
insufficient contact.
Slide the sheath off the wire and gently twist and straighten the strands.
When using the wire, be careful not to short with stray strands entering the
neighbouring poles. Do not use solder on the wire's core as this may lead to
insufficient contact.
Core
Approx.
10mm (0.39inch)
10mm (0.39inch)
Sheath
1) Using a ferrule
A ferrule can also be used to connect with the connector.
Use the ferrules in the table below for the 24VDC power supply
connector and forced stop input connector.
Use the ferrules in the table below for the 24VDC power supply
connector and forced stop input connector.
Ferrule model
Connector Wire
size
For 1 wire
For 2 wires
Crimping tool
Manufacturer
AWG16
AI1.5-10 BK
AI-TWIN2×1.5-10 BK
24VDC power supply connector
AWG14 AI2.5-10
BU
Forced stop input connector
AWG21
AI0.5-10 WH
—
CRIMPFOX-ZA3 PHOENIX
CONTACT
• Cut the wire sticking out from the end of the ferrule to 0.5mm
(0.02inch) or less.
0.5mm (0.02inch)
or less
or less
• When using a twin ferrule, be sure to insert the wire in a manner that
will keep the insulation sleeve from interfering with the neighbouring
poles. Be sure to crimp the ferrule.
poles. Be sure to crimp the ferrule.
Crimping