Chapter 13  Control Sub Functions
 
13.7.2 Skip function 
The "skip function" is used to stop (deceleration stop) the control of the positioning 
data being executed at the time of the skip signal input, and execute the next 
positioning data.   
A skip is executed by a skip command ([Cd.37] Skip command) or external command 
signal.  
The "skip function" can be used during control in which positioning data is used.   
 
The details shown below explain about the "skip function".   
 [1] Control details 
  [2] Precautions during control 
  [3] Setting the skip function from the PLC CPU 
  [4] Setting the skip function using an external command signal 
 
[1]  Control details 
The following drawing shows the skip function operation. 
 
 
[QD77MS4 operation example] 
BUSY signal
V
Deceleration by
skip signal
Start of the
next positioning 
ON
OFF
OFF
OFF
OFF
ON
ON
ON
Positioning
Positioning start signal
Positioning complete signal
Skip signal
[XC, XD, XE, XF]
 [Y10, Y11, Y12, Y13]
[X14, X15, X16, X17]
 
(Note): Refer to Section 3.3 for input/output signal of QD77MS16.
 
Fig. 13.39 Operation when a skip signal is input during positioning control 
 
[2]  Precautions during control 
(1)  If the skip signal is turned ON at the last of an operation, a deceleration stop 
will occur and the operation will be terminated.   
(2)  When a control is skipped (when the skip signal is turned ON during a 
control), the positioning complete signals will not turn ON.   
(3)  When the skip signal is turned ON during the dwell time, the remaining dwell 
time will be ignored, and the next positioning data will be executed.   
(4)  When a control is skipped during interpolation control, the reference axis 
skip signal is turned ON. When the reference axis skip signal is turned ON, 
a deceleration stop will be carried out for every axis, and the next reference 
axis positioning data will be executed.   
(5)  The M code ON signals will not turn ON when the M code output is set to 
the AFTER mode (when "1: AFTER mode" is set in "[Pr.18] M code ON 
signal output timing").   
(In this case, the M code will not be stored in "[Md.25] Valid M code".)